KUS-35W
  • 3C
  • CE
  • ROHS

Features:

·Universal AC input/Full range

·Withstand 300VAC surge input for 5 second

·Miniature size and 1U low profile,low weight

·Protections:Short circuit/Overload/Over voltage

·Cooling by free air convection

·No load power consumption<0.5W  

·LED indicator for power on

·100% full load burn-in test 

·3 years warranty


download

 

ModelKUS-35-5KUS-35-12KUS-35-15KUS-35-24KUS-35-36KUS-35-48
outputDC voltage5V12V15V24V36V48V
Rated current7A3A2.4A1.5A1A0.8A
Current range0~7A0~3A0~2.4A0~1.5A0~1A0~0.8A
Rated power35W36W36W36W36W38.4W
Ripple&noise100mVp-p120mVp-p120mVp-p150mVp-p200mVp-p200mVp-p
DC voltage ADJ. range±10%±10%±10%±10%±10%±10%
Voltage toleranceNote.3±3%±2%±1%±1%±1%±1%
Line regulationNote.4±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load regulationNote.5±2%±1%±0.5%±0.5%±0.5%±0.5%
Setup,rise,hold up time800ms,30ms,30ms/230VAC(full load)
inputVoltage range90~264VAC,127~373VDC
Frequency range47~63HZ
AC current0.7A/115VAC 0.42A/230VAC
Inrush currentCold start 45A/230VAC
Efficiency83%86%87%88%89%90%
Leakage current<0.75mA/240VAC
protectionoverloadRated output power110%~150% start over load protection
protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltageRated output voltage 115%~135% Start over voltage protection
Protection type:hiccup mode,auto-recovery after fault condition is removed
environmentWorking temp,humidity-30℃~+70℃(Please refer to“derating curve”)
20%~90%RH Non-condensing
Storage temp,humidity-40℃~+85℃,10%~95%RH non-condensing
Withstand vibration10~500HZ,2G10min/1cycle,period for 60 minutes,each axes
safetyWithstand voltageI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Isolation resistanceI/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC
Fit standardSafety standardsCompliance to UL60950-1,TUV EN60950-1,GB4943
EMC emissionCompliance to EN55022(CISPR22)Class B,GB9254 Class B,EN55014,EN61000-3-2,3
EMC immunityCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1
othersDimension99*82*30mm(L*W*H)
Weight/packing0.23kg/60pcs/14.8kg/0.025m³/0.88CUFT
MTBF≥720K hrs min. MIL-HDBK-217F(25℃)
note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation is measured from 0% to 100% rated load
6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft)
7.The power supply is considered as a component which will be installed into a finalequipment.The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests.

 

KUS35W.png