HOMESWITCHING POWER SUPPLYEnclosed Type Power SupplyEnclosed switching power supply
NEW PRODUCTS SHOW
contact us
KCS-600W
  • 3C
  • CE
  • ROHS

Features:

·AC input voltage range selected by switch

·Small volume,low weight,high efficiency

·Protections:short circuit/over load/over voltage/over temp
·
Built-in cooling DC fan

·Cooling fan ON-OFF auto control

·LED indicator for power on

·100% full load burn-in test 

·2 years warranty

 

download
ModelKCS-600-12KCS-600-13.5KCS-600-15KCS-600-24KCS-600-36KCS-600-48
outputDC voltage12V13.5V15V24V36V48V
Voltage tolerance±2%±1%±1%±1%±1%±1%
Rated current50A44.5A40A25A16.6A12.5A
Current range0~50A0~44.5A0~40A0~25A0~16.6A0~12.5A
Rated power600W600.8W600W600W597.6W600W
Ripple&noise150mvp-p150mvp-p150mvp-p180mvp-p200mvp-p200mvp-p
DCvoltage ADJ.range±10%±10%±10%±10%±10%±10%
inputVoltage range90~132VAC/180~264VAC(selected by switch),255~373VDC
frequency47~63HZ
AC current12A/115VAC,6.0A/230VAC
efficiency82%82%83%84%85%86%
Inrush currentCold start current25A/115VAC,50A/230VAC
Leakage current< 3.5mA/240VAC
protectionoverloadRated output power105%~135% start over load protection
protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltage15.6~17.8V15.6~17.8V18.6~20.8V30.6~33.2V42.6~44.2V54.8~56.6V
Protection type:hiccup mode,auto-recovery after fault condition is removed
Over temperature≥55℃fan on,≤50℃fan off,≥85℃start over temperature protection
protection type:hiccup mode,auto-recovery after temperature become normal
environmentWorking temp,humidity-10℃~+60℃,20%~90%RH
Storage temp,humidity-20℃~+85℃,10%~95%RH non-condensing
Withstand vibration10~500HZ,2G10min/1cycle,period for 60 minutes,each axes
safetyWithstand voltageI/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistanceI/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC
Fit standardSafety standardCompliance to UL1012
EMC standardCompliance to EN55022,CLASSA
othersDimension238*124*65mm(L*W*H)
Weight/packing1.5kg/12pcs/19kg/0.033m³/1.18CUFT
note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.

 