KC-120W

Features:

·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·Indicator for power on/charge/electric supply(LED)
·100% full load burn-in test 
·
Battery protection at low voltage
·2 years warranty

 

download
ModelKC-120-12KC-120-24
outputDC voltageCH1:13.8VCH1:13.4VCH1:27.6VCH2:26.5V
Voltage tolerance±1%-----±1%-----
Rated current8A0.5A4A0.3A
Current range0~8A-----0~4A-----
Rated power117.1W118.4W
Ripple&noise120mvp-p-----180mvp-p-----
DCvoltage ADJ.rangeCH1:11.3~14.9VCH1:21.3~29.8V
inputVoltage range90~264VAC,127~370VDC
frequency47~63HZ
AC current2.8A/115VAC,1.4A/230VAC
efficiency81%83%
Inrush currentCold start current 30A/115VAC,50A/230VAC
Leakage current< 1mA/240VAC
protectionOver loadRated output power110%~150% start over load protection
protection mode: AC charging mode:hiccup mode auto-recovery after fault condition is removed
Batteryprotection9.5~11V20~22V
At low voltageprotection mode:cutoff output
FunctionUPS introductionlong-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop harging when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch,no switch time,no need human guard,
cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs
environmentWorking temp,humidity-10℃~+60℃,20%~90%RH
Storagetemp,humidity-20℃~+85℃,10%~95%RH non-condensing
Withstand vibration10~500HZ,2G10min/1cycle,period for 60 minutes,each axes
safetyWithstand voltageI/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistanceI/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC
FitstandardSafety standardCompliance to UL60950-1
EMC standardCompliance to EN55022,CLASSB
othersDimension159*97*38mm(L*W*H)
Weight/packing0.56kg/45pcs/26kg/0.041m³/1.45CUFT
note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.

 

KC120W.jpg